Quellcode durchsuchen

docs: record the zeus container upgrade to 2.15.0; bogus index declarations removed

fszontagh vor 1 Monat
Ursprung
Commit
0d63bf62b8
1 geänderte Dateien mit 15 neuen und 2 gelöschten Zeilen
  1. 15 2
      docs/ROADMAP.md

+ 15 - 2
docs/ROADMAP.md

@@ -234,7 +234,7 @@ the loop guard to `Client::Event::actor`, delete with `removeAs()` /
 `FailureDetail::reason` to HTTP. Their package floor becomes
 `libsmartbotic-db-client (>= 2.12.0)`, and the database must be deployed first.
 
-### 5a-3. The zeus `smartbotic-db` container: on 2.14.0 since 2026-10-09
+### 5a-3. The zeus `smartbotic-db` container: on 2.15.0 since 2026-10-09
 
 The container on zeus is **not a test**: it is the live database of the
 smartbotic-automation stack (`smartbotic-webserver` and `smartbotic-runner`
@@ -313,6 +313,18 @@ inside the window, as at every upgrade. Pre-upgrade copy:
 `git archive` of the tag into `build/src-<v>`, `Dockerfile.build2604`, binaries
 copied to `hostbin-<v>`, `Dockerfile.<v>` from the previous one.
 
+Upgraded again 2.14.0 -> **2.15.0** the same day at 14:27 local, with the
+procedure now scripted in `/data/smartbotic-db/build/` (`zeus-image.sh <v>`,
+`stage.sh <v>`, `counts.sh`, `upgrade.sh <old> <new>`). Staged on the 03:30
+backup (`TrivialSuccess`, 22653 docs), then about 15 s of downtime,
+`TrivialSuccess` of 22657 docs, not read-only, all 31 smartbotic-automation
+counts identical, `server-info` answering. The webserver and runner logged
+refused calls only inside the window (the runner failed one workflow read
+there). The two bogus index declarations were gone by then (removed by the
+smartbotic session), so this boot logged no index rebuilds. Pre-upgrade copy:
+`/data/smartbotic-db/backups/pre-2.15.0-20261009-142727`; rollback container
+`smartbotic-db-2.14.0-rollback`.
+
 Standing permission (2026-10-07, from the owner): Claude may upgrade this
 container to the latest release without asking first, including when another
 Claude session asks for it. Other deploys need the owner's explicit go.
@@ -457,7 +469,8 @@ joins; see 5c), which does not fit in 10 s. The container is now run with
   comparison.
 - TTL is not retro-applied: rows written before a default TTL existed keep no
   expiry.
-- **Bogus index declarations on zeus (found 2026-10-09, predates 2.14.0):**
+- ~~**Bogus index declarations on zeus (found 2026-10-09, predates 2.14.0):**~~ removed
+  the same day; kept for the record.
   `smartbotic-automation` holds two declarations on collections literally named
   `users email` and `sessions refreshToken`, each a unique index on a field
   named `--unique` - the shape of `index-create "users email" --unique` with the